GL7-HSV

GL7-HSV High-Speed Voltage Module GL 7000 Data Acquisition Equipment

Quantity
Add Quotation


This is the high-speed sampling voltage input module capable to measure
high-speed voltage as control signal in inverter-based system, output of
sensors in the characteristic test, output of vibration/displacement meter,
and others. It can capture the signal by a high resolution using 16-bit
converter even if it is sampled at fast speed as maximum 1MS/s (1μs interval).

Application examples

GL7-HSV specification

Item Description
Type of module Voltage measurement module - High-speed sampling model -
Model number GL7-HSV
Number of input channels 4 channels
Input method All channels isolated unbalanced input, Simultaneous sampling,
BNC connector
Sampling speed (interval) 1 M Samples/s to 1 Sample/h (1μs to 1 hr.)
Built in RAM 2 million samples for each channel
Measurement range 100, 200, 500 m , 1, 2, 5, 10, 20, 50, 100 V, and 1-5 V Full Scale
Measurement accuracy (*1) ±0.25% of Full Scale
A/D converter Successive approximation type, 16 bits (effective resolution: 1/40000 of the measuring full range)
Input impedance 1 M ±5%
Maximum input voltage Between (+)/(-) terminal 100 m to 1 V range: 60 VP-p,
2 V to 100 V range: 100 VP-p
Between channels ((-) terminals) 60 VP-p
Between channel/GND 60 VP-p
Max. voltage (withstand) Between channels 1000 VP-p (1 minute)
Between channel/GND 1000 VP-p (1 minute)
Isolation Between input/GND Min. 50 M (at 500 V DC)
Common-mode rejection ratio Min. 90 dB (50/60 Hz, Signal source impedance: Max. 300 Ω)
Frequency response DC to 200 kHz (+1/-3 dB)
Filter Low pass Off, Line(1.5 Hz), 5, 50, 500, 5k, 50k Hz (at -3 dB, 6dB/cot)
External dimensions (W×D×H) Approx. 49 x 136 x 160 mm (Excluding projections)
Weight Approx. 740 g
*1
Subject to the conditions:
¡ñ Room temperature is 23ºC ±5ºC. ¡ñ When 30 minutes or more have elapsed
after power was turned on.
¡ñ Filter is set to 10 or Line. ¡ñ Sampling rate is set to 1 second.
¡ñ GND terminal is connected to ground.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in
Subscribe Newsletter