High temperature chamber furnaces with SiC Rod heating up to 1600ˇăC
Previous | 7 / 7 | Next |
View old post here.
These powerful laboratory muffle furnaces are available for temperatures up to 1400 °C, 1500 °C, 1550 °C or 1600 °C. The durability of the SiC rods in periodic use, in combination with their high heating speed, make these high-temperature furnaces to all-rounders in the laboratory. Heating times of 40 minutes to 1400 °C can be achieved, depending on the furnace model and the conditions of use.
- Tmax 1400 °C, 1500 °C, 1550 °C or 1600 °C
- Working temperature 1500 °C (for high-temperature furnaces LHTC ../16), increased wear and tear must be expected in case of working at higher temperatures
- Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
- Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
- Optional flap door (LHTC) which can be used as work platform or lift door (LHTCT) with hot surface facing away from the operator (High-temperature furnace LHTCT 01/16 only with lift door)
- Switching system with solid-state-relays, power tuned to the SiC rods
- Easy replacement of heating rods
- Adjustable air inlet opening, exhaust air opening in the roof
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
- Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
- Square saggar for charging of up to three layers
- Lid for top saggar
- Manual or automatic gas supply system
- Process control and documentation via VCD software package for monitoring, documentation and control\
Model | Tmax °C | Inner dimensions in mm | Volume in l | Outer dimensions in mm | Connected load kW | Electrical connection | Weight in kg | Minutes to Tmax | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
W | D | H | W | D | H | |||||||
LHTC(T) 03/14 | 1400 | 120 | 210 | 120 | 3.0 | 415 | 545 | 490 | 9.0 | 3-phase | 30 | 40 |
LHTC(T) 08/14 | 1400 | 170 | 290 | 170 | 8.0 | 490 | 625 | 540 | 13.0 | 3-phase | 40 | 40 |
LHTC(T) 03/15 | 1500 | 120 | 210 | 120 | 3.0 | 415 | 545 | 490 | 9.0 | 3-phase | 30 | 50 |
LHTC(T) 08/15 | 1500 | 170 | 290 | 170 | 8.0 | 490 | 625 | 540 | 13.0 | 3-phase | 40 | 50 |
LHTCT 01/16 | 1550 | 110 | 120 | 120 | 1.5 | 340 | 300 | 460 | 3.5 | single-phase | 18 | 40 |
LHTC(T) 03/16 | 1600 | 120 | 210 | 120 | 3.0 | 415 | 545 | 590 | 9.0 | 3-phase | 30 | 60 |
LHTC(T) 08/16 | 1600 | 170 | 290 | 170 | 8.0 | 490 | 625 | 540 | 13.0 | 3-phase | 40 | 60 |