Obsnap Instruments Sdn Bhd
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.
+603-5621 5786
+603-5621 5829
+60122185651 (Enquiry)
+60162233687 (Vacancy)

Fungilab - CAPILLARY Cannon-Fenske (Opaque & Routine)

Previous 14 / 22 Next

Fungilab - CAPILLARY Cannon-Fenske (Opaque & Routine) Viscometer Coating / Paint Testing

Quantity
Add Quotation


Features

All capillary viscometers are supplied with the calibration certificate issued in accor- dance with the conditions of accreditation granted by a National Metrological Register which has assessed the measurement capability of the laboratory, the test uncertainty and its traceability to recognized international standards UKAS. *Fungilab offers many types of glass capillary viscometers that are not listed in our catalog. We can also manufacture glass capillary viscometers with customer-specified constants. Viscometers with special constants, added temps, and before/after data are available by special order. For further information contact Fungilab.

CANNON-FENSKE OPAQUE

ASTM D-445-446, ASTM D2515, ISO 3104-3105 and UNE 400313 Cannon-Fenske Opaque Viscometers (reverse flow type) are used for dark Newto- nian liquids; especially suitable for liquids so dark in colour that cannot be seen in a Cannon-Fenske routine viscometer. Also used to study shearing stress and shearing rate. Sample volume: aprox. 12 ml. Precision: ±0.3%. Value indicated at 40ºC and 100ºC in both bulbs.
CODE DESCRIPTION VISCOSITY RANGE MATERIAL CONSTANT K APPROX. INCLUDED
CV004-101 Cannon-Fenske Opaque size 25 0.4 - 2 cSt Glass 0.002 Capillary Tube - Calibration Certificate
CV004-102 Cannon-Fenske Opaque size 50 0.8 - 4 cSt Glass 0.004 Capillary Tube - Calibration Certificate
CV004-103 Cannon-Fenske Opaque size 75 1.6 - 8 cSt Glass 0.008 Capillary Tube - Calibration Certificate
CV004-104 Cannon-Fenske Opaque size 100 3 - 15 cSt Glass 0.015 Capillary Tube - Calibration Certificate
CV004-105 Cannon-Fenske Opaque size 150 7 - 35 cSt Glass 0.035 Capillary Tube - Calibration Certificate
CV004-106 Cannon-Fenske Opaque size 200 20 - 100 cSt Glass 0.1 Capillary Tube - Calibration Certificate
CV004-107 Cannon-Fenske Opaque size 300 50 - 200 cSt Glass 0.25 Capillary Tube - Calibration Certificate
CV004-108 Cannon-Fenske Opaque size 350 100 - 500 cSt Glass 0.5 Capillary Tube - Calibration Certificate
CV004-109 Cannon-Fenske Opaque size 400 240 - 1.200 cSt Glass 1.2 Capillary Tube - Calibration Certificate
CV004-110 Cannon-Fenske Opaque size 450 500 - 2.500 cSt Glass 2.5 Capillary Tube - Calibration Certificate
CV004-111 Cannon-Fenske Opaque size 500 1.600 - 8.000 cSt Glass 8 Capillary Tube - Calibration Certificate
CV004-112 Cannon-Fenske Opaque size 600 4.000 - 20.000 cSt Glass 20 Capillary Tube - Calibration Certificate
CV004-113 Cannon-Fenske Opaque size 650 9.000 - 45.000 cSt Glass 45 Capillary Tube - Calibration Certificate
CV004-114 Cannon-Fenske Opaque size 700 20.000 - 100.000 cSt Glass 100 Capillary Tube - Calibration Certificate

CANNON-FENSKE ROUTINE

ASTM D-445-446, ASTM D2515, ISO 3104-3105 and UNE 400313 Cannon-Fenske Routine Viscometers quickly and easily measure the viscosities of transparent Newtonian liquids. Sample volume: aprox. 7 ml. Precision: ±0.2%. With constant value indication at +40 ºC and +100ºC.
CODE DESCRIPTION VISCOSITY RANGE MATERIAL CONSTANT K APPROX. INCLUDED
CV004-201 cannon-Fenske routine size 25 0.5 - 2 cSt Glass 0.002 Capillary Tube - Calibration Certificate
CV004-202 cannon-Fenske routine size 50 0.8 - 4 cSt Glass 0.005 Capillary Tube - Calibration Certificate
CV004-203 cannon-Fenske routine size 75 1.6 - 8 cSt Glass 0.008 Capillary Tube - Calibration Certificate
CV004-204 cannon-Fenske routine size 100 3 - 15 cSt Glass 0.015 Capillary Tube - Calibration Certificate
CV004-205 cannon-Fenske routine size 150 7 - 35 cSt Glass 0.035 Capillary Tube - Calibration Certificate
CV004-206 cannon-Fenske routine size 200 20 - 100 cSt Glass 0.1 Capillary Tube - Calibration Certificate
CV004-207 cannon-Fenske routine size 300 50 - 200 cSt Glass 0.25 Capillary Tube - Calibration Certificate
CV004-208 cannon-Fenske routine size 350 100 - 500 cSt Glass 0.5 Capillary Tube - Calibration Certificate
CV004-209 cannon-Fenske routine size 400 240 - 1.200 cSt Glass 1.2 Capillary Tube - Calibration Certificate
CV004-210 cannon-Fenske routine size 450 500 - 2.500 cSt Glass 2.5 Capillary Tube - Calibration Certificate
CV004-211 cannon-Fenske routine size 500 1.600 - 8.000 cSt Glass 8 Capillary Tube - Calibration Certificate
CV004-212 cannon-Fenske routine size 600 4.000 - 20.000 cSt Glass 20 Capillary Tube - Calibration Certificate
CV004-213 cannon-Fenske routine size 650 9.000 - 45.000 cSt Glass 45 Capillary Tube - Calibration Certificate
CV004-214 cannon-Fenske routine size 700 20.000 - 100.000 cSt Glass 100 Capillary Tube - Calibration Certificate

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in
Subscribe Newsletter