Obsnap Instruments Sdn Bhd
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.
+603-5621 5786
+603-5621 5829
+60122185651 (Enquiry)
+60162233687 (Vacancy)

ElektroPhysik - Digital Coating Thickness Gauges - MiniTest 70

Previous 6 / 20 Next

ElektroPhysik - Digital Coating Thickness Gauges - MiniTest 70 Coating Thickness Gauges Coating / Paint Testing

Quantity
Add Quotation


Overview

Application

Non destructive measurement of:

  • Non-magnetic coatings like varnishes, enamels, chromium and zinc on ferromagnetic base materials (e.g. steel)
  • Insulating coatings like varnishes and anodic coatings on non-ferrous metals (e.g. aluminium, copper, austenitic stainless steel, brass)

Features

  • Accurate coating measurement of up to 3mm(F range) and 2.5 mm(N range)
  • Dual sensor for automatic substrate identification and setting the suitable measuring principle: eddy currents or magnetic induction (not in model F))
  • Wear-resistant probes with long service life
  • Lightweight: only 80 grams
  • Dual sensor for automatic identification of the substrate (FN model). According to the substrate, it adjusts to the appropriate measuring principle: magnetic induction or eddy currents principle.
  • Quick statistics mode to calculate the number of readings, average, standard deviation and min., max. value
  • lightweight: 80 grams / 2.8 oz only

Scope of delivery

  • MiniTest 70 device with integrated sensor
  • Operating instructions
  • 1 AA cell, type LR06
  • Zero reference plate(s)
  • Control standard
  • Belt pouch

Property Value
Measuring range
N: 0 mm - 2.5 mm/ 100 mils
F: 0 mm - 3 mm/ 120 mils
Measuring principle
magnetic-induction/eddy currents
Signal processing
Sensor integrated 32-bit signal processing (SIDSP®)
Accuracy
± (1.5 μm + 3% of reading) with 1-point calibration ± (0.06 mils + 3% of reading) with 1-point calibration ± (1.5 μm + 2% of reading) with 2-point calibration2 ± (0.06 mils + 2% of reading) with 2-point calibration2
Repeatability
± (1 μm + 1% of reading) / ± (0.04 mils + 1% of reading)
Low range resolution
0.5 µm
0.02 mils
Minimum curvature radius convex
5 mm
0.2 ''
Minimum curvature radius concave
40 mm
1.60 ''
Minimum substrate thickness
F: 0.5 mm - 0.02 ''
N: 0.04 mm - 0.0016 ''
Measuring units
metric/imperial switchable
Calibration
standard, 1-point and 2-point calibration
Statistics
n, x, s, Min, Max
Operating temperature
-10 °C - 60 °C
14 °F - 140 °F
Storing temperature
-20 °C - 70 °C
-4 °F - 158 °F
Power supply
1x AA (Mignon)-battery
International standards
DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882, ASTM B 244, B 499, D7091, E 376
Dimensions
approx. 157 mm length, Ø 27 mm; 5.2' length, Ø 1.06'
Weight
~ 80 grams, 2.8 oz
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in
Subscribe Newsletter