Edge EC Conductivity / TDS Water / Liquid Analysis

Quantity
Add Quotation


Hanna Instruments is proud to introduce the world’s most innovative EC meter: edge®.

edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

pH Specifications

pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy (@25ºC/77ºF) ±0.2 mV, ±0.01 pH, ±0.002 pH
pH Calibration up to 5 points
pH Calibration Buffers 1.68, 10.01, 12.45, 4.01, 6.86, 7.01, 9.18, two custom buffers
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*

EC Specifications

EC Range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy (@25ºC/77ºF) ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm

TDS Specifications

TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy (@25ºC/77ºF) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
TDS Conversion Factor 0.40 to 0.80

Salinity Specifications

Salinity Range 0.0 to 400.0% NaCl, 0.01 to 42.00 PSU, 0.0 to 80.0 g/L*
Salinity Resolution 0.1% NaCl, 0.01 PSU, 0.01 g/L
Salinity Accuracy (@25ºC/77ºF) ±1% of reading
Salinity Calibration 1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)

DO Specifications

DO Range 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation
DO Resolution 0.01 ppm, 0.1% saturation
DO Accuracy ±1 digit, ±1.5% of reading
DO Calibration one or two points at 0% (HI 7040 solution) and 100% (in air)
DO Temperature Compensation ATC: 0 to 50 ºC; 32.0 to 122.0 °F
Salinity Compenstaion 0 to 40 g/L (with 1 g/L resolution)
DO Altitude Compensation -500 to 4000 m (with 100 m resolution)

Temperature Specifications

Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±1.0 °F

Additional Specifications

EC/TDS/Salinity Temperature Compensation Automatic -5 to 100º C (23 to 212º F) NoTC - can be selected to measure absolute conductivity.
Conductivity Temperature Coefficient 0.00 to 6.00% / ºC
pH Electrode Diagnostics Glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
Logging up to 1000*** records organized in: Manual log-on-demand (Max. 200 logs), Manual log-on-stability (Max. 200 logs), Interval logging *** (Max. 600 samples; 100 lots)
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information HI2030 EC kit includes: HI763100 Conductivity probe, 3 sachets of 1413 μS/cm conductivity standard, 3 sachets of 12880 μS/cm conductivity standard, USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual and Quality certificate.
Notes

* temperature limits will be reduced to actual probe/sensor limits
** with temperature compensation function disabled
*** For standard mode only (logging)

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in
Subscribe Newsletter