Multiparameter Photometer for Environmental Testing HI83206
Previous | 10 / 24 | Next |
- Light blocking cuvette holder
- Backlit LCD
- BEPS (Battery Error Prevention System) Alerts users in the event a low battery could effect readings
- PC compatible via USB
- Powered by rechargeable batteries or 12 VDC
- Save and recall logged data at the touch of a button.
- On-screen tutorial; with the tutorial function enabled, short guides relating to current operation are displayed.
- HELP button; screen specific help can viewed at the touch of a button.
- Method selection; users can easily select parameters via the Method button.
- Setup button; instrument preferences such as backlight intensity and screen contrast can be changed via the setup button.
HI 83206 is a multiparameter bench photometer dedicated to environmental testing. Critical environmental parameters such as pH, dissolved oxygen, nitrite, ammonia, chlorine and phosphorus or pollutants like chromium VI, nickel, silver and zinc can be monitored with this meter. This instrument measures 24 different methods, and has four measuring channels for a wide range of tests.
The optical system of HI 83206 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results.
HI 83206 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu, and the Help Menu provides assistance for every step in the measurement process. This meter can be connected to a PC via a USB cable, where the data can be managed with optional HI 92000 Windows® compatible software.
Order Information:
HI 83206-01 (115V) and HI 83206-02 (230V) are supplied with sample cuvettes and caps (3 ea), cloth for wiping cuvettes (1), 60 mL glass bottle for dissolved oxygen (1), scissors, AC/DC power adapter and instruction manual.
Specifications
Light Source | up to 5 tungsten lamps with different narrow band interference filters. | |
Light Detector | silicon photocell | |
Power Supply | external 12 VDC power adapter or built-in rechargeable battery | |
Environment | 0 to 50°C (32 to 122°F); max 90% RH non-condensing | |
Dimensions | 235 x 200 x 110 mm (9.2 x 7.87 x 4.33") | |
Weight | 0.9 Kg (2 lbs.) |
Multi Parameter Specifications
Parameter | Range | Method | Reagent Code |
---|---|---|---|
Ammonia LR | 0.00 to 3.00 mg/L (ppm) | Nessler | HI 93700-01 |
Ammonia MR | 0.00 to 10.00 mg/L (ppm) | Nessler | HI 93715-01 |
Chlorine, Free | 0.00 to 2.50 mg/L (ppm) | DPD | HI 93701-01 |
Chlorine, Total | 0.00 to 3.50 mg/L (ppm) | DPD | HI 93711-01 |
Chromium VI HR | 0 to 1000 µg/L | Diphenylcarbohydrazide | HI 93723-01 |
Chromium VI LR | 0 to 300 µg/L | Diphenylcarbohydrazide | HI 93749-01 |
Color of Water | 0 to 500 PCU |
Colorimetric platinum cobalt |
— |
Copper HR | 0.00 to 5.00 mg/L (ppm) | Bicinchoninate | HI 93702-01 |
Copper LR | 0 to 1000 µg/L | Bicinchoninate | HI 95747-01 |
Cyanuric Acid | 0 to 80 mg/L (ppm) | Turbidimetric | HI 93722-01 |
Molybdenum | 0.0 to 40.0 mg/L (ppm) | Mercaptoacetic Acid | HI 93730-01 |
Nickel HR | 0.00 to 7.00 g/L | Photometric | HI 93726-01 |
Nickel LR | 0.000 to 1.000 mg/L (ppm) | PAN | HI 93740-01 |
Nitrate | 0.0 to 30.0 mg/L (ppm) | Cadmium Reduction | HI 93728-01 |
Nitrite HR | 0 to 150 mg/L (ppm) | Ferrous Sulfate | HI 93708-01 |
Nitrite LR | 0.00 to 1.15 mg/L (ppm) | Diazotization | HI 93707-01 |
Oxygen, Dissolved |
0.0 to 10.0 mg/L (ppm) | Winkler | HI 93732-01 |
pH | 6.5 to 8.5 pH | Phenol Red | HI 93710-01 |
Phosphate HR | 0.0 to 30.0 mg/L (ppm) | Amino Acid | HI 93717-01 |
Phosphate LR | 0.00 to 2.50 mg/L (ppm) | Ascorbic Acid | HI 93713-01 |
Phosphorus | 0.0 to 15.0 mg/L (ppm) | Amino Acid | HI 93706-01 |
Silica | 0.00 to 2.00 mg/L (ppm) | Heteropoly blue | HI 93705-01 |
Silver | 0.000 to 1.000 mg/L (ppm) | PAN | HI 93737-01 |