Obsnap Instruments Sdn Bhd
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.
+603-5621 5786
+603-5621 5829
+60122185651 (Enquiry)
+60162233687 (Vacancy)

Nitrate Portable Photometers Hi96786

Previous 7 / 24 Next

Nitrate Portable Photometers Hi96786 Photometers  Water / Liquid Analysis

Quantity
Add Quotation


  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

Nitrates are present in nature as a result of decomposition of organic microorganisms or due to their use as fertilizers. Nitrates reduce to nitrites, which in turn easily combine to form substances dangerous to man.

A maximum level of 45 mg/L (ppm) is established as a worldwide guideline for nitrate concentration in water. In Europe, the maximum consented level of nitrates in potable water is 50.0 mg/L (ppm), while in the USA the EPA has established a guideline for the maximum level of nitrate—nitrogen of 10 mg/L (NO-3-N), which corresponds to 45.0 mg/L of nitrates.

The HI 96786 meter measures the nitrate content in water and wastewater.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

Order Information:
HI 96786 are supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 9786C include photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.

Specifications

Range 0.0 to 100 mg/L (ppm) nitrate
Resolution 1 mg/L
Accuracy @ 25°C ±5 mg/L ±5% of reading
Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 525 nm
Power Supply 9V battery
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7')
Weight 360 g (12.7 oz.)
Method adaptation of cadmium reaction method
Notes Chloride above 100 mg/L will cause a negative interference with the nitrate chemistry. We do not recommend the HI96786 for measuring nitrate in saltwater.
Warranty 2 years

 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in
Subscribe Newsletter