Previous | 3 / 24 | Next |
- CAL Check™ Validation and Calibration
- Built-in Timer
- Automatic Shut Off
Details
The HI96750 portable photometer is for the measurement of potassium. Hanna's portable photometers feature an advanced optical system; the combination of a light emitting diode, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Features at-a-glance
CAL Check™ - Allows for performance verification and calibration of the meter using NIST traceable standards.
GLP - Review of the last calibration date.
Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on.
Battery status indicator - Indicates the amount of battery life left.
Built-in timer - Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.
Error messages - Messages on display alerting to problems including no cap, high zero, and standard too low.
Cooling lamp indicator - To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.
Units of measure - Appropriate unit of measure is displayed along with reading.
Specifications
Range | Potassium LR (P1): 0.0 to 10.0 mg/L (ppm); Potassium MR (P2): 10 to 100 mg/L (ppm) |
Resolution | Potassium LR (P1): 0.1 mg/L; Potassium MR (P2): 1 mg/L |
Accuracy @ 25°C (77°F) | Potassium LR (P1): ±1.5 mg/L ±7% of reading; Potassium MR (P2): ±15 mg/L ±7% of reading |
Light Source | light emitting diode |
Light Detector | silicon photocell with narrow band interference filter @ 466 nm |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Battery Type | 9V battery |
Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Weight | 360g (12.7oz.) |
Ordering Information | HI96750 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate, and instruction manual. CAL Check™ standards and testing reagents sold separately. |
Warranty | 2 years |